• Verify that the PC has an IP address on the 192.168.2.xxx network by
typing ipconfig /all in a command window on the PC.
If the PC did not receive the address, it may be necessary to release and
renew the PC's IP address using the ipconfig command in a command
window.
• Open a web browser on the PC and enter http://192.168.2.254 into the
browser's address field. The Px's Configuration screen is displayed.
• Navigate to the Boot Server IP Address field. Enter the IP address of the
Allworx Server on which the Px will be installed.
• Scroll to the New Password field. If it is empty, the Px's administrator
password has not been set. We recommend you create a site-specific
password and enter it into the New Password field. Re-enter the password
in the Confirm Password field.
• Click Update. The Px's Update Result screen is displayed.
• Click Restart and click OK on the confirmation box.
• As soon as the Power LED begins flashing, disconnect the Ethernet
cable from the Px's Network port.
• When the Power LED lights solid amber, disconnect power.
• Connect the Px to the site's network then apply power.
The Px's Power LED will flash green for up to three minutes. When it stops
flashing and lights solid green, the upgrade as well as installation of the Px
on the Allworx server is complete.
If the site's DHCP server does not support DHCP Option 66, the Px's
network settings must be configured manually. Manually configure the Px's
network settings by performing procedure B, above.
-What are the server requirements for the Px 6/2 Expander?
1. Server Software Release 6.9 or higher: Software is located in the
Allworx Partner portal under Support & Training > Software. System
software release 6.9 or higher must be downloaded to the server and
activated to enable the Px 6/2 Expander.
2. Allworx Internet Call Access key: For Allworx 24x, 10x and 6x
systems, running software earlier than 7.1, that will be installed with 1,2, or